ElectricalPanelUpgrade.net
An AeqR network property

HomeGuides

Homeowner guide

100-amp vs 200-amp service: do you actually need the upgrade?

Published 2026-09-10 · Fairfield County, CT · Every figure below carries a dated source at the end of the page.

Short version. A 100A service gives you about 24,000 watts on paper and roughly 19,000 watts of comfortable continuous headroom; 200A gives 48,000 and about 38,000. If you are adding any two of heat pump, EV charger, induction range, hot tub or a second dryer/oven, the calculation almost always lands on 200A. If you only need more breaker spaces, a subpanel may be the cheaper fix.

What the numbers mean

Service amperage times 240 volts is the raw capacity: 100A × 240V = 24,000 W; 200A × 240V = 48,000 W. Practical continuous capacity is 80% of that — about 19,200 W and 38,400 W — because continuous loads are sized at 125% under the NEC. Those are the two ceilings every load calculation is measured against.

The NEC 220.82 calculation, without the jargon

Electricians size a dwelling service with the "optional method" in NEC §220.82. It is four lines:

  1. General lighting and receptacles: 3 VA per square foot of living space. A 2,400 sq ft colonial = 7,200 VA.
  2. Small-appliance and laundry circuits: 1,500 VA each; a typical kitchen has two plus one laundry = 4,500 VA.
  3. Fixed appliances at nameplate: range, oven, dryer, water heater, dishwasher, disposal, microwave, EV charger, hot tub — add them all up.
  4. Apply demand: 100% of the first 10,000 VA, 40% of everything after that, then add the largest of heating or cooling at 100%. Divide by 240 to get amps.

Worked example from an exam prep source: 39,700 VA of connected load becomes 24,825 VA of demand, or 103 A — just over a 100A service, which is why so many 1960s–1990s Fairfield County houses sit right at the line before anyone adds a charger.

What pushes a house over 100A

AdditionTypical circuitLoad in the calc
Level 2 EV charger, 48A60A, 240V11,500 VA continuous (NEC 625.42)
Level 2 EV charger, 32A40A, 240V7,700 VA continuous
Cold-climate heat pump (3–4 ton) with backup strips30–60A8,000–15,000 VA (largest of heat/cool at 100%)
Induction range40–50A8,000–12,000 VA nameplate
Heat pump water heater30A4,500 VA
Hot tub50A10,000–12,000 VA
Central AC, 3 ton30A~4,500 VA

Two of these on top of a normal all-electric kitchen and dryer is where the 100A math stops working. One of them, in a gas-heated house, often fits.

Which code applies in Connecticut right now

Connecticut enforces the 2022 State Building Code, which adopts the 2020 NEC (effective October 1, 2022). The 2026 code, adopting the 2023 NEC, was scheduled for July 1, 2026 and is delayed pending regulatory review as of the state's adoption page. Your electrician and town inspector work to whichever is in force on the permit date; the load calculation is the same under both.

Three honest outcomes

Ask the electrician to show the calculation. It's a one-page form; if they won't produce it, they're guessing.

Ready for a real number?

Planning ranges are not quotes. A licensed Connecticut electrician prices your panel after seeing it.

Request a free estimate →
Sources (checked 2026-09-10)
  1. NEC §220.82 optional dwelling calculation, explained (ExpertCE) — https://expertce.com/learn-articles/dwelling-service-calculation-optional-method-nec-220-82/ — page dated 2025-11-28
  2. NEC §230.79(C) minimum 100A service, worked example (Dakota Prep) — https://www.dakotaprep.com/nec-exam-guides/guide-to-service-size-calculation-questions-on-nec-electrical-exams — page dated 2026-09-08
  3. What a 200-amp service can carry (Home Inspection Insider) — https://homeinspectioninsider.com/how-many-watts-can-a-200-amp-house-handle/ — page dated 2024-02-04
  4. NEC §625.42 EV loads are continuous (text) — https://www.electricallicenserenewal.com/Electrical-Continuing-Education-Courses/NEC-Content.php?sectionID=1534 — no date on page
  5. Eversource CT Electric Service FAQ — standard residential service is 200A — https://www.eversource.com/residential/about/doing-business-with-us/builders-contractors/electric-service-faq — no date on page
  6. Wilton CT — 2022 CT State Building Code (2020 NEC) effective Oct 1, 2022 — https://www.wiltonct.gov/building-department/pages/ct-state-building-code-information — no date on page
  7. CT DAS — code adoption process, 2026 code (2023 NEC) pending — https://portal.ct.gov/das/office-of-state-building-inspector/building-and-fire-code-adoption-process — no date on page

Questions homeowners ask

Does the code require 200 amps?

No. NEC §230.79(C) sets a 100A minimum for a one-family dwelling. 200A is the practical standard because Eversource's standard residential service is 200A and because heat pumps, EV chargers and induction ranges each take a large share of a 100A service.

Can I add an EV charger to a 100-amp service?

Sometimes. A 48A charger is a 60A continuous load; on a 100A service that leaves little headroom once heat, range and dryer are counted. A load calculation decides it — or a load-management device that throttles the charger. Many Fairfield County homes with electric heat or a heat pump cannot.

What is the 80% rule people mention?

Continuous loads (three hours or more — EV charging is defined as continuous under NEC §625.42) are sized at 125% of the load, which is the same as saying a breaker should carry no more than 80% of its rating continuously. It is why a 40A charger needs a 50A circuit.

Get a real number for your house

One licensed Connecticut electrician calls you back. Never sold to a list.

No obligation. Submitting does not opt you in to text messages; texting is a separate, optional checkbox on the form. See Privacy and Terms.

Currently fulfilled by: R. Piro Electric LLC · CT license ELC.0200504-E1 · (203) 880-5995 · Fairfield County and New Haven County, Connecticut.
ElectricalPanelUpgrade.net is an AeqR network property. Requests are routed to one licensed Connecticut electrical contractor; provider assignment may change. Provider facts verified 2026-09-05.